Fire Fighting · Delhi NCR

Fire Sprinklers Dealer & Stockist in Delhi

Sprinkler selection comes down to four things: orientation, temperature rating, K-factor and listing. Pendent for false ceilings, upright for exposed pipework, sidewall where you cannot drop a branch line. 68°C is standard for offices and residences; 79°C or higher near kitchens, boiler rooms and skylights where ambient heat would cause nuisance operation. Everything we supply is UL listed or FM approved, because unlisted sprinklers will not pass an insurance audit.

Pendent fire sprinkler with red glass bulb, frame arms and deflector discharging spray
Pendent sprinkler — UL listed and FM approved, 68°C and 79°C, K5.6 and K8.0

Fire Sprinklers — sizes, materials and specifications we supply

SpecificationDetails
TypesPendent, upright, sidewall (horizontal & vertical), concealed with cover plate, recessed
Temperature ratings68°C (red), 79°C (yellow), 93°C (green), 141°C (blue)
K-factorK5.6 (½" / 15 mm), K8.0 (¾" / 20 mm), K11.2 for storage
ResponseQuick response (3 mm bulb) and standard response (5 mm bulb)
FinishBrass, chrome plated, white polyester
ApprovalsUL listed, FM approved; ISI marked options
AccessoriesRosette / escutcheon plates, sprinkler guards, spare head boxes, sprinkler wrenches, flexible drop hoses

Where these are used

Offices and IT parks, shopping malls and retail, hotels and hospitals, residential high-rise, warehouses and cold storage, car parks, manufacturing plants, data centres (pre-action systems).

Why buy your Fire Sprinklers from Namokar Enterprises?

We are a Delhi-based stockist, not a broker. That means the material you order is either on our floor in Chawri Bazar or coming direct from the manufacturer against our standing order — so the price you are quoted is the price you pay, and the delivery date you are given is one we control.

  • Ready stock of common sizes for same-day dispatch in Delhi NCR
  • Genuine brands only — Sant, Zoloto, Kartar, L&T, Audco, Advance, Jindal
  • Test certificates and ISI/IBR/UL documentation supplied with the invoice
  • Written quotations with item-wise rates, GST and freight — usually the same day
  • Technical help before you order, so you buy the right thing once
Request a Quotation →

Send your requirement

Item list, BOQ, drawing or even a photo of a hand-written list — whatever you have.

Tapping send opens WhatsApp with your details filled in — no account or sign-up needed.

Fire Sprinklers — common questions

What is the difference between pendent and upright sprinklers?
A pendent sprinkler hangs down from the branch line, usually through a false ceiling, and its deflector throws water downward and outward. An upright sprinkler sits on top of the pipe and throws water up against the deflector and then out, which avoids the pipe itself shadowing the spray. Use upright where pipework is exposed, pendent where there is a ceiling. They are not interchangeable — fitting a pendent head upright will leave a dry shadow.
Which temperature rating should I choose?
68°C (red bulb) for normal occupancies where ambient stays below about 38°C. Move to 79°C (yellow) near kitchens, in unventilated attics, close to skylights and around heat-producing equipment, otherwise you get nuisance discharge. Very hot areas such as boiler houses need 93°C or higher.
What does the K-factor mean?
K-factor is the discharge coefficient — it tells you how much water the head delivers at a given pressure. K5.6 is the standard ½" head used in light and ordinary hazard occupancies; K8.0 delivers more water at the same pressure and is used for higher hazard and storage applications. The hydraulic design determines which one your system needs.

Need a price today?

Send us your BOQ, drawing or item list on WhatsApp and get a written quotation the same working day. Ready stock for most sizes at our Delhi godown.

💬 WhatsApp Your Requirement 📞 +91 99996 83666
💬